Leader of cleaning technologies

Service provider for general scheme of cleanroom

promotion@szsxjh.com  

Mobile website

About us          Products                News

            

all rights reserved © Suzhou Sothis Purification Equipment Factory   
苏ICP备05019691号-1

Business Consulting:  0512-67525878(24-hour service)
E-mail:  promotion@szsxjh.com
Add:  272 Road Suzhou Guandul
Zip code:  215031

Powered by www.300.cn

Links:Industrial Safety Cabinet   Dust Removal Equipment   Steel Wire Thread Sleeve   Liu'an Generator Lease   Jinan Zhongsong   Vertical Mixer   Bengbu Lighting Project   Constant Pressure Frequency Conversion Water Supply Equipment

Dust Monitor    Intelligent Barrier Gate   Box Pasting Machine Belt   High-pressure Steam Sterilizer   Anaerobic Incubator   Reinforcing Mesh   Nanjing Epoxy Floor   Rotary Evaporator   GMP Workshop Purification Project   Laboratory Design   Scree   Wuhan Stainless Steel Water Tank   Foamed Ceramics   Henan Purification Project   Zhengzhou Dust Screen   Private Hospital Purchase

SX-L1053U Filter test rig

Name

SX-L1053U Filter test rig

First.  TheSX-L1053filterefficiencytestbenchissuitablefortestingtheefficiencyof95%-99.99%gradefiltermediaandtestingthefiltermaterialaccordingtotheinternationalstandard.Thedesignstructureofthetesttable
产品型号
SX-L1053U
没有此类产品
Details
First.
 
 
The SX-L1053 filter efficiency test bench is suitable for testing the efficiency of 95%-99.99% grade filter media and testing the filter material according to the international standard. The design structure of the test table is compact and portable, and in the process of testing, it only needs to provide the appropriate supply of power and compressed air (no water, no oil), suitable for use in the laboratory, factory and other occasions.
 
 
In the filter paper test, the particle counting method is used to measure the diameter efficiency. Monodisperse aerosol is recommended in the experiment. The measurement of pressure drop should be carried out at the specified filter rate.
 
 
The filter paper is fixed on the fixture, and the test air volume corresponds to the required filtration rate. The aerosol generated by the aerosol generator is adjusted and then electrostatic neutralized (PSL), and then mixed with the filtered test air, and then into the test area through the filter material.
 
 
To measure efficiency, an air diverge is carried out upstream and downstream of the filter material. The particle counting instrument is used to measure the counting concentration of particles in the sampling airstream, and the efficiency is obtained through the ratio of upstream to downstream.
 
 
In addition, the resistance of filter material should be measured, and the flow of control should be adjusted manually.
 
 
Products meet JJF1190-2008 "dust particle counter calibration specification".
 
 
Reference standard:
 
 
Performance test methods for JG / T22-1999 general ventilation filters
 
 
Test method of ANSI / ASHRAE52.1-1992 general air purifier in USA
 
 
European EN779:2002 air filters for general ventilation - Determination of filtration performance
 
 
Test methods for JISB9908:2001 ventilation air filters and electric air purifiers in Japan
 
 
European EN1822 high efficiency filter
 
 
ISO-29463 high efficiency filter and filter medium for removing particulate matter in air

 

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待
Next article

Products