Leader of cleaning technologies

Service provider for general scheme of cleanroom

promotion@szsxjh.com  

Mobile website

About us          Products                News

            

all rights reserved © Suzhou Sothis Purification Equipment Factory   
苏ICP备05019691号-1

Business Consulting:  0512-67525878(24-hour service)
E-mail:  promotion@szsxjh.com
Add:  272 Road Suzhou Guandul
Zip code:  215031

Powered by www.300.cn

Links:Industrial Safety Cabinet   Dust Removal Equipment   Steel Wire Thread Sleeve   Liu'an Generator Lease   Jinan Zhongsong   Vertical Mixer   Bengbu Lighting Project   Constant Pressure Frequency Conversion Water Supply Equipment

Dust Monitor    Intelligent Barrier Gate   Box Pasting Machine Belt   High-pressure Steam Sterilizer   Anaerobic Incubator   Reinforcing Mesh   Nanjing Epoxy Floor   Rotary Evaporator   GMP Workshop Purification Project   Laboratory Design   Scree   Wuhan Stainless Steel Water Tank   Foamed Ceramics   Henan Purification Project   Zhengzhou Dust Screen   Private Hospital Purchase

Filter integrity tester

Name

Filter integrity tester

Filterintegritytester(filtercountingleakdetector)  SX-L310S  1.Productdescription  SX-L310Shighefficiencyfiltercountleakdetector(patentnumber:ZL2012201478)isdesignedaccordingtotherequirementsofISO1463
产品型号
SX-L310S
没有此类产品
Details
Filter integrity tester (filter counting leak detector)
 
 
SX-L310S
 
 
1. Product description
 
 
SX-L310S high efficiency filter count leak detector (patent number: ZL2012201478) is designed according to the requirements of ISO14633-3 B.6.3 and IEST-RP-CC034.2 specification. It is a special instrument for the clean room (area) high efficiency air port scan leak detection. It is composed of three parts: aerosol generator, particle diluent and counting leak detector (with handheld intelligent scanning probe). Yes.
 
 
The SX-L310S high efficiency filter count leak detector uses counting method to scan the leak detection, through the count leak detector and the particle counter to detect the upstream concentration of the filter, and calculate the downstream leakage point according to the efficiency of the filter, and compare the leakage point value of the lower reaches of the high efficiency air port by the actual scanning and compare with the calculated leakage point. Leak detection of high efficiency tuyere. The third part of GB/T25915 "clean room and related controlled environment", appendix B.6.3 details the procedures for counting the leak detection, GB50591 "clean room construction and acceptance standard" recommended leak should be preferred counting scanning method.

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待

Products